![]() ![]() After selecting the block make sure directory is pointing to iec library folder (was nfpa). There is also a library of drawings available in the Drives and Motion Accelerator Toolkit ( ). If you insert same symbol on the same drawing, you may need to swap the blocks (preciously you had issue with) using command AESWAPBLOCK, select option B. I use the product drawing library on the AB's website to find the panel footprints and then add the attributes needed for AutoCAD electrical.Replace NPFA with IEC as shown below (marked in RED), then save and close.Open WD.ENV (in notepad) which is in the AeData folder (along with the Proj and Tutorial folders).Are they IEC or NFPA (I guess they are NFPA)? Click + of the Schematic Libraries to find out the default symbol libraries. 3 3d drawings you need autocad electric symbols drawing top electric symbols cad library autocad drawing in dwg web electric symbols free cad drawings on.In the Project Settings tab click Schematic Libraries then click Default. Check your project properties: right click project> properties.Check your project Settings: right click project>Settings, in the lower window you can see what symbol libraries are used – IEC or NFPA?.What is happening here is your project is IEC standard project ie it supposed to symbols from IEC library folder whereas ACADE is defaulted to NFPA standard ie WD.ENV file is telling ACADE to use NFPA Symbols instead. ![]()